3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT

3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT

Product Details:

Place of Origin: China
Brand Name: TIAN RUI
Certification: ROHS REACH
Model Number: 3RD-8S

Payment & Shipping Terms:

Minimum Order Quantity: 1000PCS
Price: Negotiable
Packaging Details: 1000pcs/PE bag
Delivery Time: 5-7 days
Payment Terms: D/P,T/T,Paypal,Western Union
Supply Ability: 1000000+PCS+Month
Get Best Price Contact Now

Detail Information

Product Name: 3RD-8S Gas Discharge Tubes 8/20μs Impulse Currency: 20KA
DC Spark-over Voltage: 75V-600V Lead Type: SMD
Electrode Numbers: 3 Electrodes Ultra Low Capacitance: Max 1.5pF
Size: 8mmX10mm Operating Temperature: -40 To +90℃
Weight: 2.0g Application: Broadband Equipment
High Light:

SMD Type GDT Gas Discharge Tube

,

3 Electrodes GDT Gas Discharge Tube

,

20KA GDT Tube

Product Description

3RD-8S Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT

 

Description of 3RD-8S Gas Discharge Tube

 

GDT is placed in front of, and in parallel with, sensitive telecom equipment such as power lines, communication lines, signal lines and data transmission lines to help protect them from damage caused by transient surge voltages that may result from lightning strikes and equipment switching operations. These devices do not influence the signal in normal operation. However, in the event of an overvoltage surge, such as a
lightning strike, the GDT switches to a low impedance state and diverts the energy away from the sensitive equipment.

 

Our GDT offer a high level of surge protection, a broad voltage range, low capacitance, and many form factors including new surface mount devices, which makes them suitable for applications such as Main Distribution Frame (MDF) modules, high data-rate telecom applications (e.g. ADSL, VDSL), and surge protection on power lines. Their low capacitance also results in less signal distortion. When used in a coordinated
circuit protection solution with PolySwitch devices, they can help equipment manufacturers meet stringent safety regulatory standards.

 

3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT 0

3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT 1

 

Features of 3 Poles Electrodes Gas Discharge Tube

 

• Excellent response to fast rising transients
• Stable breakdown voltage
• GHz working frequency
• 8/20μs Impulse current capability: 20KA
• Non-Radioactive
• Ultra Low capacitance (<1.5pF)
• High insulation resistance
• Lead-free compliant
• RoHS and REACH compliant
• Size: Ф8mm*10mm
• Storage and operational temperature: -40~+90°C

 

Applications of 75V-600V Gas Discharge Tube Arresters

 

• Communication equipment
• CATV equipment
• Data lines
• Power supplies
• Telecom SLIC protection
• Broadband equipment
• ADSL equipment, including ADSL2+
• XDSL equipment
• Satellite and CATV equipment
• Test equipment
• Consumer electronics

 

3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT 2

 

Electrical Characteristics of 20KA GDT Gas Discharge Tube

 

Part Number DC Spark-over Voltage 1) 2) 3) @100V/S Impulse Spark-over Voltage 3) Insulation Resistance 4) Capacitance @1MHz Life Ratings
Impulse Discharge Current
@8/20μs 5)
AC Discharge Current @50Hz 1S 5) Impulse Life @10/1000μS 200A 5)
100V/μS 1KV/μS
Max Max Min Max Nominal
±5 times
Max 1 time Nominal 5 times Min
V V V pF KA KA A Times
3R075SD-8S 75±20% 500 600 1 1.5 20 25 20 300
3R090SD-8S 90±20% 500 600 1 1.5 20 25 20 300
3R150SD-8S 150±20% 500 600 1 1.5 20 25 20 300
3R230SD-8S 230±20% 600 700 1 1.5 20 25 20 300
3R250SD-8S 250±20% 600 700 1 1.5 20 25 20 300
3R350SD-8S 350±20% 800 900 1 1.5 20 25 20 300
3R420SD-8S 420±20% 850 950 1 1.5 20 25 20 300
3R470SD-8S 470±20% 900 1000 1 1.5 20 25 20 300
3R600SD-8S 600±20% 1100 1200 1 1.5 20 25 20 300
Glow Voltage at 10mA ~60V
Arc Voltage at 1A....................................................................................... ~10V
Glow to Arc transition Current ~1A
Operation and storage temperature………………………………..….......... -40~+90°C
Climatic category (IEC60068-1) 40/90/21
Weight ~2.0g
Surface treatment………………………………………….....…………......... Matte-tin plated
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
3) Tip or ring electrode to center electrode
4) Insulation Resistance Measuring Voltage:
75V at DC 25V
90V~150V at DC 50V
Other at DC 100V
5) Total current through center electrode, half value through tip respectively ring electrode. Terms in accordance with ITU-T Rec. K.12, IEC 61643-311, GB/T 9043.

 

3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT 3

Symbol Millimeters Inches
A 8±0.2 0.315±0.008
B 8±0.2 0.315±0.008
C 10±0.3 0.394±0.012
D Φ8±0.2 Φ0.315±0.008
E Φ7.2±0.1 Φ0.283±0.004
F 0.5±0.1 0.020±0.004
G 1.5±0.1 0.059±0.004
H 0.5±0.1 0.020±0.004
X 1.5 0.059
X1 1.5 0.059
X2 10.0 0.394
Y 6.0 0.236

 

3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT 4

Symbol Millimeters Inches
W 16±0.3 0.630±0.012
A0 10.5±0.1 0.413±0.004
B0 8.3±0.1 0.327±0.004
K0 8.4±0.1 0.331±0.004
P 16±0.1 0.630±0.004
F 7.5±0.1 0.295±0.004
E 1.75±0.1 0.069±0.004
D 1.5+0.1/-0.0 0.059+0.004/-0.0
P0 4±0.1 0.157±0.004
P2 2±0.1 0.079±0.004
T 0.4±0.1 0.016±0.004
D0 13.3±0.15 0.524±0.006
D1 330±2 12.992±0.079
D2 100+1/-2 3.937+0.039/-0.079
W1 16.5±0.4 0.65±0.016

 

Soldering Parameters - Reflow Soldering (Surface Mount Devices)

 
3RD-8S GDT Gas Discharge Tube Arresters 3 Poles Electrodes 75V-600V 20KA 8mmX10mm SMD Type GDT 5
 
Reflow Condition Pb - Free assembly
Pre Heat -Temperature Min (Ts(min)) 150°C
-Temperature Max (Ts(max)) 200°C
- Time (min to max) (ts) 60 -180 Seconds
Average ramp up rate ( Liquids Temp TL) to peak 3°C/second max
TS(max) to TL - Ramp-up Rate 5°C/second max
Reflow - Temperature (TL) (Liquids) 217°C
- Time (min to max) (ts) 60 -150 Seconds
Peak Temperature (TP) 260 +0/-5°C
Time within 5°C of actual peak Temperature (tp) 10 - 30 Seconds
Ramp-down Rate 6°C/second max
Time 25°C to peak Temperature (TP) 8 minutes Max
Do not exceed 260°C
 